Endeavour Energy Business Tariffs — FY2026-27

Follow

Network tariff price components effective 1 July 2026 (ex GST).

N91 — GS STOU

Type: Time-of-use

Comments: Default tariff for low voltage non-residential customers (and all new/greenfield non-residential sites). Peak 4pm–8pm business days (seasonal — higher in summer, Nov–Mar); Solar Sponge 10am–2pm every day; Off-peak all other times.

Price ComponentRate
Network fee98.88 c/day
Network Time-of-use tariff - Peak Time (Summer)25.16 c/kWh
Network Time-of-use tariff - Peak Time (Non-Summer)16.91 c/kWh
Network Time-of-use tariff - Solar Sponge Time5.17 c/kWh
Network Time-of-use tariff - Off-peak Time13.44 c/kWh

N90 — General Supply Block

Type: Block (inclining)

Comments: Usage billed in blocks — Block 1 applies up to the 120,000 kWh threshold (prorated across the billing period); the remainder is charged at the Block 2 rate.

Price ComponentRate
Network fee98.88 c/day
Network Block tariff - Block 1 (first 120,000 kWh)12.58 c/kWh
Network Block tariff - Block 2 (above 120,000 kWh)15.01 c/kWh

N92 — GS Demand

Type: Time-of-use with demand charge

Comments: Solar Sponge 10am–2pm every day; energy rate all other times, all year. Daily demand charge (kW) applies to Peak periods only, measured 4pm–8pm business days; higher in summer (Nov–Mar).

Price ComponentRate
Network fee98.88 c/day
Network Time-of-use tariff - Peak Time12.81 c/kWh
Network Time-of-use tariff - Solar Sponge Time5.17 c/kWh
Network Demand tariff - Peak (Summer)24.18 c/kW/day
Network Demand tariff - Peak (Winter)11.92 c/kW/day

N93 — GS Demand Transitional

Type: Time-of-use with demand charge

Comments: Solar Sponge 10am–2pm every day; energy rate all other times, all year. Daily demand charge (kW) applies to Peak periods only, measured 4pm–8pm business days; higher in summer (Nov–Mar).

Price ComponentRate
Network fee98.88 c/day
Network Time-of-use tariff - Peak Time13.33 c/kWh
Network Time-of-use tariff - Solar Sponge Time5.17 c/kWh
Network Demand tariff - Peak (Summer)21.76 c/kW/day
Network Demand tariff - Peak (Winter)10.73 c/kW/day

N19 — LV STOU Demand

Type: Time-of-use with kVA demand charge

Comments: Low voltage, consumption above 160 MWh per year; requires interval and demand metering. Peak 4pm–8pm business days (seasonal — higher in summer, Nov–Mar); Off-peak all other times. Daily demand charge (kVA) applies to Peak periods only, measured 4pm–8pm business days.

Price ComponentRate
Network fee2414.00 c/day
Network Time-of-use tariff - Peak Time (Summer)6.10 c/kWh
Network Time-of-use tariff - Peak Time (Non-Summer)5.53 c/kWh
Network Time-of-use tariff - Off-peak Time4.24 c/kWh
Network Demand tariff - Peak (Summer)53.11 c/kVA/day
Network Demand tariff - Peak (Non-Summer)48.33 c/kVA/day

N20 — LV STOU Demand - Embedded

Type: Time-of-use with kVA demand charge

Comments: As per N19, for embedded network parent connection points (low voltage, above 160 MWh per year, interval and demand metering). Same price components and windows as N19.

Price ComponentRate
Network fee2414.00 c/day
Network Time-of-use tariff - Peak Time (Summer)6.10 c/kWh
Network Time-of-use tariff - Peak Time (Non-Summer)5.53 c/kWh
Network Time-of-use tariff - Off-peak Time4.24 c/kWh
Network Demand tariff - Peak (Summer)53.11 c/kVA/day
Network Demand tariff - Peak (Non-Summer)48.33 c/kVA/day

N89 — LV STOU Transitional

Type: Time-of-use

Comments: Transitional tariff for customers who meet the N19 criteria but lack demand-capable metering; not available on application — Endeavour Energy intends these customers to move onto N19. Peak 4pm–8pm business days (seasonal — higher in summer, Nov–Mar); Off-peak all other times.

Price ComponentRate
Network fee2414.00 c/day
Network Time-of-use tariff - Peak Time (Summer)19.50 c/kWh
Network Time-of-use tariff - Peak Time (Non-Summer)16.63 c/kWh
Network Time-of-use tariff - Off-peak Time10.20 c/kWh

N29 — HV STOU Demand

Type: Time-of-use with kVA demand charge

Comments: High voltage supply (nominally 12.7 kV SWER, 11 or 22 kV); requires interval and demand metering. Peak 4pm–8pm business days (seasonal — higher in summer, Nov–Mar); Off-peak all other times. Daily demand charge (kVA) applies to Peak periods only, measured 4pm–8pm business days.

Price ComponentRate
Network fee8465.00 c/day
Network Time-of-use tariff - Peak Time (Summer)2.94 c/kWh
Network Time-of-use tariff - Peak Time (Non-Summer)2.87 c/kWh
Network Time-of-use tariff - Off-peak Time2.72 c/kWh
Network Demand tariff - Peak (Summer)41.96 c/kVA/day
Network Demand tariff - Peak (Non-Summer)41.40 c/kVA/day

N95 — Storage

Type: Two-way (import and export)

Comments: Low Voltage Grid Connected Storage. For storage devices connected to the LV network solely to import electricity for later export from the same connection point; consumption must be under 160 MWh per year. Import: Peak 4pm–8pm business days (seasonal — higher in summer, Nov–Mar); Solar Sponge 10am–2pm every day at 0.00 c/kWh; Off-peak all other times. Export: reward for exporting during the evening peak (seasonal); charge on exports during the solar sponge window above the threshold of 8 kWh/day (block, totalled across the billing period); exports at all other times attract no charge or reward.

Price ComponentRate
Network fee173.33 c/day
Network Time-of-use tariff - Peak Time (Summer)13.73 c/kWh
Network Time-of-use tariff - Peak Time (Non-Summer)5.49 c/kWh
Network Time-of-use tariff - Solar Sponge Time0.00 c/kWh
Network Time-of-use tariff - Off-peak Time2.02 c/kWh
Network Time of Export tariff - Export Reward (Summer)-11.71 c/kWh
Network Time of Export tariff - Export Reward (Non-Summer)-3.47 c/kWh
Network Time of Export tariff - Export Charge1.86 c/kWh

N50 — Controlled Load 1

Type: Controlled load (dedicated circuit)

Comments: Secondary tariff on a controlled circuit, available where a Residential or General Supply tariff also applies. Anytime rate on the controlled channel.

Price ComponentRate
Network fee11.87 c/day
Network Controlled load tariff4.82 c/kWh

N54 — Controlled Load 2

Type: Controlled load (dedicated circuit)

Comments: Secondary tariff on a controlled circuit, available where a Residential or General Supply tariff also applies. Anytime rate on the controlled channel.

Price ComponentRate
Network fee11.87 c/day
Network Controlled load tariff7.38 c/kWh

N61 — Prosumer

Type: Two-way (export)

Comments: Pays a reward for exporting during the evening peak (4pm–8pm) on business days — higher in summer (Nov–Mar); applies a charge on exports during the solar sponge window (10am–2pm) every day. Export threshold: 8 kWh/day (block, totalled across the billing period). Exports at all other times attract no charge or reward. Opt-in secondary tariff applied alongside N91, N92 or N93 for General Supply customers.

Price ComponentRate
Network Time of Export tariff - Export Reward (Summer)-11.71 c/kWh
Network Time of Export tariff - Export Reward (Non-Summer)-3.47 c/kWh
Network Time of Export tariff - Export Charge1.86 c/kWh

Charges applying to all Endeavour Energy tariffs

Price ComponentRate
Environmental charge (regulated)1.01 c/kWh
Market charge0.96 c/kWh
Amber hedging1.00 c/kWh
Environmental offset (GreenPower)0.73 c/kWh
Metering charge (general supply)38.53 c/day
Was this article helpful?
0 out of 0 found this helpful

Comments

0 comments

Please sign in to leave a comment.